s3 detail specific mcsgp method parameters (YMC America)
Structured Review

S3 Detail Specific Mcsgp Method Parameters, supplied by YMC America, used in various techniques. Bioz Stars score: 94/100, based on 18 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/s3+detail+specific+mcsgp+method+parameters/MCSGP/10__1021_slash_acs__oprd__4c00513-170-3-18
Average 94 stars, based on 18 article reviews
Images
1) Product Images from "Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP)"
Article Title: Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP)
Journal: Organic Process Research & Development
doi: 10.1021/acs.oprd.4c00513
Figure Legend Snippet: Figure 1. Twin column chromatography system setup for MCSGP (Contichrom CUBE, YMC ChromaCon).
Techniques Used: Column Chromatography
Figure Legend Snippet: Figure 2. MCSGP process. (A) An MCSGP run with 4 cycles is shown as an example. A short startup step is needed to preload column 1 with feed before the main cyclic phase of MCSGP begins. Each cycle consists of an elution from column 1 (switch 1red) and an elution from column 2 (switch 2blue), respectively. Alternating elutions can continue indefinitely for “n” cycles until the feed is consumed. To finish the MCSGP run, a shutdown step consisting of a single elution without any refeeding is done. (B) A detailed schematic representation of a single MCSGP “switch” is shown. This consists of four phases: P1 = phase 1 (elution + regeneration); P2 = phase 2 (elution with weak recycling); P3 = phase 3 (product collection + refeeding); and P4 = phase 4 (elution with strong recycling). Columns are operated in parallel during P1 and P3; columns are interconnected for product recycling in P2 and P4. The position of the columns alternates switch to switch, allowing for continuous operation (yellow arrows indicate column interchange between switches). See Section 2.4 for a more complete description of the MCSGP process principle.
Techniques Used:
Figure Legend Snippet: Figure 3. Single-column AIEX chromatographic profiles and the MCSGP design. (A) Black line: representative chromatogram of pilot-scale single- column batch production run showing absorbance UV@290 nm vs column volumes (CV) overlaid with %B modifier concentration (purification using the AKTA pure 150 M). The pilot-scale method was downscaled 78.6× and run on the Contichrom CUBE. (B) MCSGP design chromatogram. Absorbance UV@280 nm is overlaid with product purity (area% HPLC-UV). Product purity was measured by HPLC analysis, and each dot represents an analyzed fraction. Phases P1 to P4, as described in Figure 2B, are highlighted showing where MCSGP recycling and product collection boundaries were set. (C) - The MCSGP Wizard v8.1 software simplifies method creation.
Techniques Used: Concentration Assay, Purification, Software
Figure Legend Snippet: Figure 4. (A, B) MCSGP chromatographic profiles showing absorbance UV@280 nm and %B (A) or UV@280 nm and conductivity (mS/cm) (B) plotted vs time (min). (A) Plot showing 13 consecutive MCSGP cycles including startup and shutdown (total of 27 product elutions). (B) Plot showing an overlay of 13 consecutive MCSGP cycles. (C, D) Plots showing the total area under the curve (AUC) in (mAU×mL) vs cycle number. Each dot is the sum of 2 elutions from 2 switches. (C) Black line: total AUC. Red line: AUC for the product collection window. (D) Blue line: AUC for the weak recycling phase. Green line: AUC for the strong recycling phase.
Techniques Used:
Figure Legend Snippet: Figure 5. MCSGP product quality evaluation. (A) Plot showing cycle to cycle MCSGP target product yield (%) and mass recovered (mg). (B) Plot showing cycle to cycle product purity HPLC-UV (area%) vs impurity N-1 content HPLC-UV (area%). (C) Analytical HPLC chromatograms (UV Abs at 260 nm, normalized and then zoomed in to show impurities). Blue line is the crude feed material (85 area% purity). Orange line is the 13 cycle MCSGP product pool (95.4 area% purity).
Techniques Used:
Related Articles
Column Chromatography:Article Title: Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP) Article Snippet: Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.. Tables S2 and Concentration Assay:Article Title: Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP) Article Snippet: Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.. Tables S2 and Purification:Article Title: Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP) Article Snippet: Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.. Tables S2 and Software:Article Title: Continuous Purification of a Conjugated Short Interfering RNA Therapeutic Using Anion Exchange Twin-Column Chromatography (MCSGP) Article Snippet: Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.Table 3 shows the MCSGP parameters including the mobile phase composition, flow rate, and volume for each chromatographic step, including startup, main, and shutdown methods.. Tables S2 and |